Stephen Hicks
Title
Cited by
Cited by
Year
Design of floors for vibration : a new approach
AL Smith, SJ Hicks, PJ Devine, SCIG Britain)
Steel Construction Institute, 2009
2092009
Design of composite asymmetric cellular beams and beams with large web openings
RM Lawson, J Lim, SJ Hicks, WI Simms
Journal of Constructional Steel Research 62 (6), 614-629, 2006
1322006
An experimental study on strength and serviceability of reinforced and steel fibre reinforced concrete (SFRC) continuous composite slabs
A Gholamhoseini, A Khanlou, G MacRae, A Scott, S Hicks, R Leon
Engineering Structures 114, 171-180, 2016
412016
Design of floor structures for human induced vibrations
M Feldmann, C Heinemeyer, C Butz, E Caetano, A Cunha, F Galanti, ...
JRC–ECCS joint report, 2009
412009
Composite slabs and beams using steel decking: best practice for design and construction
JW Rackham, GH Couchman, SJ Hicks
Metal Cladding & Roofing Manufacturers Association in partnership with the …, 2009
382009
System reliability evaluation of steel frames with semi-rigid connections
HT Thai, B Uy, WH Kang, S Hicks
Journal of Constructional Steel Research 121, 29-39, 2016
362016
Design of composite beams with large web openings
RM Lawson, SJ Hicks
SCI P355, 2011
332011
Strength and ductility of headed stud connectors welded in modern profiled steel sheeting
S Hicks
Steel Construction 44 (1), 2-10, 2010
33*2010
Strength and ductility of headed stud connectors welded in modern profiled sheeting
S Hicks
Structural Engineer 85 (10), 32-39, 2007
332007
Vibration characteristics of steel–concrete composite floor systems
S Hicks
Progress in Structural Engineering and Materials 6 (1), 21-38, 2004
332004
Design of Composite Beams with Large Web Openings : In Accordance with Eurocodes and the UK National Annexes
RM Lawson, SJ Hicks
Steel Construction Institute, 2011
302011
Design of floors for vibration: A new approach (SCI P354)
AL Smith, SJ Hicks, PJ Devine
SCI, Ascot, Berkshire, 2007
292007
Fire behaviour of slender, highly utilized, eccentrically loaded concrete filled tubular columns
N Mago, SJ Hicks
Journal of Constructional Steel Research 119, 123-132, 2016
272016
Stud Shear Connectors in Composite Beams that Support Slabs with Profiled Steel Sheeting
SJ Hicks, AL Smith
Structural Engineering International 24 (2), 246-253, 2014
272014
Design strength of concrete-filled steel columns
WH Kang, B Uy, Z Tao, S Hicks
Advanced Steel Construction 11 (2), 165-184, 2015
242015
Design of composite beams using precast concrete slabs
SJ Hicks, RM Lawson
232003
Generalisation of criteria for floor vibrations for industrial, office, residential and public building and gymnastic halls
G Sedlacek, C Heinemeyer, C Butz, B Veiling, P Waarts, F Van Duin, ...
EUR, 1-343, 2006
222006
Design guide on the vibration of floors in hospitals
SJ Hicks, PJ Devine
SCI PUBLICATION, 2004
222004
Shear performance of steel fibre-reinforced concrete
A Khanlou, GA MacRae, AN Scott, SJ Hicks, GC Clifton
Australasian Structural Engineering Conference 2012, 400-407, 2012
202012
Comparative structure cost of modern commercial buildings
SJ Hicks
Steel construction Institute, 2004
202004
The system can't perform the operation now. Try again later.
Articles 1–20